V-tech PC6 Manual User Manual

Browse online or download User Manual for Accessories for electrical V-tech PC6 Manual. V-Tech PC6 Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1. Introduction:
The PC6 is a power comb unit,which is designed for DT 2
wire system to supply power for outdoor station, indoor
monitor and other accessories. It can work both as a nor-
mal power comb and auxiliary power comb. The features
are as follows:
• Universal AC input/full range
• Multi protection: short circuit, overload, over voltage
• Integrated with DT-DPS(power separator), Additional
DT-DPS is not needed.
• Support up to 4~8 monitors(depend on models)
• DIN rail mounting
2. Terminal Description:
4. Wiring:
Open the AC cover:
1. push the cover bottom
towards the center with
your hand;
2. turn over and pull it out.
After connect the AC cable,
it is suggested to close the cover.
PC6 Power Comb Instructions
5. Specication:
Input Voltage: 100~240Vac
Input Frequency: 50~60Hz
Rated Output Voltage: DC 28V+2V
Rated Output Current: 1.5A
Working Temperature: -10
0
C~50
0
C
SW Port Input Voltage: Max.230Vac, 2A
Dimension: 140*90*60mm
3. Mounting:
Step1: Mount the din rail to the wall with screws ;
Step2: Pull down the mounting buckle,then hang the
unit on din rail.
N: AC input.
L: AC input.
SW: switch terminal. It can extend to connect light or
lock.
LED: power indicator,always on when plug in power.
CN2: normal power comb or auxiliary power comb se-
lection terminal. Please refer to part 4.
CN1: bus control terminal.
BUS(IM): indoor monitor connection terminal.
BUS(DS): door station connection terminal.
Note:
1. the AC cable is not included in the package, it must
comply with requirements of dierent country.
2. If N,SW terminal is connected light or lock, CN1
terminal must connect SC6 controller to support this
function.
3. pin1&2 should be short-circuited with a C3-3P
line(included in the package) if the unit work as a nor-
mal power comb. But if it work as a auxiliary power
comb, pin 1&2 should be taken o.
6. Warning:
- The unit can only be used in DT 2 wire products sup-
plied by our company.
- Don’t connect the unit with any non-specified power
source. Fire or electric shock could result.
- Don’t dismantle or alter the unit. Fire or electric shock
could result.
- The unit must be installed and wired by a qualified
technician.
- Keep the unit away from water or any other liquid. Fire
or electric shock could result.
We reserve the right to modify the specication in this manual at any time without notice.
Din rail
Din rail
Mounting Buckle
N N L SW
LED
CN1CN2
1 2 3
BUS(IM) BUS(DS)
N N L SW
AC~
connect to light/lock
CN1CN2
1 2 3
BUS(IM)
Connect to monitor Connect to door staiton
BUS(DS)
Page view 0
1

Summary of Contents

Page 1 - PC6 Power Comb Instructions

1. Introduction:The PC6 is a power comb unit,which is designed for DT 2 wire system to supply power for outdoor station, indoor monitor and other acce

Comments to this Manuals